116 research outputs found

    Redundancy Strategies for a High Splitting Optically Amplified Passive Optical Network

    Get PDF
    Copyright IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.High splitting, optically amplified, passive optical networks (SuperPONs) are investigated in terms of redundancy provision and protection mechanisms. Options for redundancy, including the important special case of dual homing, are detailed, and it is determined as to which of these options (duplication of the feeder and first distribution section, and N+1 protection of the optical amplifiers in the amplified splitter) would be required to be provided to all attached users to facilitate appropriate availability of the basic telephony service. The distributed amplified splitter dual homing solution is found to outperform the single amplified splitter solution in terms of its survivability. The protection mechanisms necessary to automatically switch to the redundant provision are discussed and it is seen that with the aid of suitable regular precautionary procedures protection switching can generally be provided rapidly (<50 ms). Finally, an availability, and cost versus availability, study confirms the aforementioned redundancy assessment for fiber-to-the-home (FTTH) implementations, but shows fiber-to-the-curb (FTTC) as needing additional redundancyPeer reviewe

    First demonstration of a Compton gamma imager based on silicon photomultipliers

    Full text link
    We are developing a rugged and person-transportable Compton gamma imager for use in security investigations of radioactive materials, and for radiological incident remediation. The imager is composed of layers of scintillator with light collection for the forward layers provided by silicon photomultipliers and for the rear layer by photomultiplier tubes. As a first step, we have developed a 1/5th-scale demonstration unit of the final imager. We present the imaging performance of this demonstration unit for Cs-137 at angles of up to 30 degrees off-axis. Results are also presented for Sn-113 and Na-22. This represents the first demonstration of the use of silicon photomultipliers as an embedded component for light collection in a Compton gamma imager.Comment: 19 pages, 6 figure

    Two-loop corrections to the decay rate of parapositronium

    Full text link
    Order α2\alpha^2 corrections to the decay rate of parapositronium are calculated. A QED scattering calculation of the amplitude for electron-positron annihilation into two photons at threshold is combined with the technique of effective field theory to determine an NRQED Hamiltonian, which is then used in a bound state calculation to determine the decay rate. Our result for the two-loop correction is 5.1243(33)5.1243(33) in units of (α/π)2(\alpha/\pi)^2 times the lowest order rate. This is consistent with but more precise than the result 5.1(3)5.1(3) of a previous calculation.Comment: 26 pages, 7 figure

    Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector

    Full text link
    The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.Comment: Submitted to NIMA Proceedings, SORMA XII. 9 pages, 4 figure

    Psychosocial stress and brain function in adolescent psychopathology

    Get PDF
    Objective: To explore how conduct, hyperactivity/inattention, and emotional symptoms are associated with neural reactivity to social-emotional stimuli, and the extent to which psychosocial stress modulates these relationships. Method: Participants were community adolescents recruited as part of the European IMAGEN study. Bilateral amygdala regions of interest were used to assess the relationship between the three symptom domains with fMRI neural reactivity during passive viewing of dynamic angry and neutral facial expressions. Exploratory functional connectivity and whole-brain multiple regression approaches were used to analyze how the symptoms and psychosocial stress relate to other brain regions. Results: In response to the social-emotional stimuli, adolescents with high levels of conduct or hyperactivity/inattention symptoms showed hyperactivity of the amygdala, and several regions across the brain, when they experienced a greater number of stressful life events. This effect was not observed with emotional symptoms. A cluster in the mid-cingulate was found to be common to both conduct problems and hyperactivity symptoms. Exploratory functional connectivity analyses suggested amygdala-precuneus connectivity is associated with hyperactivity/inattention symptoms. Conclusions: The results link hyperactive amygdala responses, and regions critical for top-down emotional processing, with high levels of psychosocial stress in individuals with greater conduct and hyperactivity/inattention symptoms. This work highlights the importance of studying how psychosocial stress impacts functional brain responses to social-emotional stimuli, particularly in adolescents with externalizing symptoms

    The Majorana Neutrinoless Double-Beta Decay Experiment

    Full text link
    The proposed Majorana double-beta decay experiment is based on an array of segmented intrinsic Ge detectors with a total mass of 500 kg of Ge isotopically enriched to 86% in 76Ge. A discussion is given of background reduction by: material selection, detector segmentation, pulse shape analysis, and electro-formation of copper parts and granularity. Predictions of the experimental sensitivity are given. For an experimental running time of 10 years over the construction and operation of Majorana, a half-life sensitivity of ~4x10^27 y (neutrinoless) is predicted. This corresponds to an effective Majorana mass of the electron neutrino of ~0.03-0.04 eV, according to recent QRPA and RQRPA matrix element calculations.Comment: 10 pages, 7 figure

    The Majorana Demonstrator: Progress towards showing the feasibility of a tonne-scale 76Ge neutrinoless double-beta decay experiment

    Get PDF
    The Majorana Demonstrator will search for the neutrinoless double-beta decay (0vββ) of the 76Ge isotope with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own anti-particle, demonstrate that lepton number is not conserved, and provide information on the absolute mass-scale of the neutrino. The Demonstrator is being assembled at the 4850 foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be contained in a low-background environment and surrounded by passive and active shielding. The goals for the Demonstrator are: demonstrating a background rate less than 3 t-1 y-1 in the 4 keV region of interest (ROI) surrounding the 2039 keV 76Ge endpoint energy; establishing the technology required to build a tonne-scale germanium based double-beta decay experiment; testing the recent claim of observation of 0vββ [1]; and performing a direct search for light WIMPs (3-10 GeV/c2)

    Experimental progress in positronium laser physics

    Get PDF

    Characteristics of signals originating near the lithium-diffused N+ contact of high purity germanium p-type point contact detectors

    Get PDF
    A study of signals originating near the lithium-diffused n+ contact of p-type point contact (PPC) high purity germanium detectors (HPGe) is presented. The transition region between the active germanium and the fully dead layer of the n+ contact is examined. Energy depositions in this transition region are shown to result in partial charge collection. This provides a mechanism for events with a well defined energy to contribute to the continuum of the energy spectrum at lower energies. A novel technique to quantify the contribution from this source of background is introduced. Experiments that operate germanium detectors with a very low energy threshold may benefit from the methods presented herein
    corecore